There will always be areas in a workplace where the chances of detecting a fire early are very few and human traffic, very low - factories with large storage areas and server rooms, for instance. If a fire breaks out in such areas, putting it out becomes almost impossible.
| Nomenclature For Portable Fire Extinguisher | CM HFC227ea 5Kg MS SP Red | CM HFC227ea Fa 10Kg MS SP Red | CM HFC236 Fa 5Kg MS SP Red | CM HFC236 Fa 10Kg MS SP Red | CM FE36 5Kg MS SP Red | CM FE36 10Kg MS SP Red | CM HCFC123 5Kg MS SP Red | CM HCFC123 10Kg MS SP Red |
| Product Code | CF-000770A | CF-000771A | CF-000770 | CF-000771 | CF-000033 | CF-000034 | CF-000027 | CF-000028 |
| Agent | HFC-227ea | HFC-227ea | HFC-236fa | HFC-236fa | FE-36 | FE-36 | HCFC-123 | HCFC-123 |
| Stored Pressure / Cartridge | Stored Pressure | Stored Pressure | Stored Pressure | Stored Pressure | Stored Pressure | Stored Pressure | Stored Pressure | Stored Pressure |
| Certification or Verifing Body | EUROCERT,BSI | EUROCERT,BSI | EUROCERT | EUROCERT | EUROCERT | EUROCERT | EUROCERT | EUROCERT |
| Certification type | PED, BSI TESTED | PED, BSI TESTED | PED | PED | PED | PED | PED | PED |
| CE Marking | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Coverage Area | Not Applicable | Not Applicable | Not Applicable | Not Applicable | Not Applicable | Not Applicable | Not Applicable | Not Applicable |
| Gross Weight | 7.70 To 7.90 Kg | 14.70 To 15.10 Kg | 7.70 To 7.90 Kg | 14.70 To 15.10 Kg | 7.70 To 7.90 Kg | 14.70 To 15.10 Kg | 7.70 To 7.90 Kg | 14.70 To 15.10 Kg |
| Net Mass | 4.90 To 5.10 Kg | 9.80 To 10. 20 Kg |
4.90 To 5.10 Kg | 9.80 To 10. 20 Kg |
4.90 To 5.10 Kg | 9.80 To 10. 20 Kg |
4.90 To 5.10 Kg | 9.80 To 10. 20 Kg |
| Discharge Mechanism | Automatic | Automatic | Automatic | Automatic | Automatic | Automatic | Automatic | Automatic |
| Applicable On Fires | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C & Electrical Started Fire | A, B, C & Electrical Started Fire |
| Can Construction | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded | Deep Drawn & Mig Welded |
| Valve / Cap Construction | Forging And Machining | Forging And Machining | Forging And Machining | Forging And Machining | Forging And Machining | Forging And Machining | Forging And Machining | Forging And Machining |
| External Coating | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder | Epoxy Polyester Powder |
| Helium Leak Detection Testing | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Warranty In Years | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| Working Pressure | 10 Bar | 10 Bar | 10 Bar | 10 Bar | 10 Bar | 10 Bar | 10 Bar | 10 Bar |
| Hydrostatic Test Pressure | 35 Bar | 35 Bar | 35 Bar | 35 Bar | 35 Bar | 35 Bar | 35 Bar | 35 Bar |
| Dia. Of Shell (Od) | 240 Mm | 300 Mm | 240 Mm | 300 Mm | 240 Mm | 300 Mm | 240 Mm | 300 Mm |
| Approx. Height Of Fire Ext. | 270 Mm | 320 Mm | 270 Mm | 320 Mm | 270 Mm | 320 Mm | 270 Mm | 320 Mm |
| Body Thickness | 1.6 Mm | 2.0 Mm | 1.6 Mm | 2.0 Mm | 1.6 Mm | 2.0 Mm | 1.6 Mm | 2.0 Mm |
| Cylinder Material Spec. | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) | Steel Cr2(Dc01) |
| Operating Temperature | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc | -30Oc To +60Oc |